AC Servo Systems
SV series
Axis with keyway, Absolute, 5 kW SV-B500AK
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model | SV-B500AK | |||
General specifications | Type | Motor with electromagnetic brake, Absolute Type (ABS) | ||
Applicable servo amplifiers | SV-150*2 | |||
Rated output | 4.4 kW | |||
Rated torque | 28.4 N m | |||
Instantaneous maximum torque | 71.1 N m | |||
Rated current | 32.8 Arms | |||
Instantaneous maximum current | 84 Arms | |||
Rated rotation speed | 1500 min-1 | |||
Highest rotation speed | 3000 min-1 | |||
Torque constant | 0.934 N m/Arms | |||
Rotor moment of inertia | 76 ×10-4kg・m2 | |||
Rated power rate | 106 kW/s | |||
Rated angle acceleration | 3740 rad/s2 | |||
Excitation method | Permanent magnet | |||
Allowable load moment of inertia ratio | 5 times | |||
Resolution | 20bit | |||
Operating environment | Operating ambient temperature | 0 to +40°C (No freezing) | ||
Ambient storage temperature | -20 to +60°C (No freezing) | |||
Ambient operating/storage humidity | 20 to 80%RH (no condensation) | |||
Vibration resistance | 49 m/s2 with the servo motor flange used as reference surface | |||
Shock resistance | 490 m/s2 for two times with the servo motor flange used as reference surface | |||
Enclosure rating | Totally enclosed, self-cooling, IP67 (excluding connectors and shaft opening) | |||
Operating environment | Indoors (No corrosive gas, flammable gas, oil mist, or dust) | |||
Operating environment | Altitude | 1,000 m max. above sea level | ||
Approved standards | UL/CSA standards | UL1004 C22.2 No.100 | ||
CE marking | Low-voltage directive | EN60034-1, EN60034-5 | ||
EMI | EN55011 Class A, EN61800-3 | |||
EMS | EN61800-3 | |||
North American EMI standards | FCC Part15 B, ICES-003. Class A | |||
Insulation class | Class F | |||
Insulation withstand voltage | 1500 VAC for 1 minute | |||
Insulation resistance | 10 MΩ min. with 500 VDC megohmmeter | |||
Weight | Approx 23.5kg | |||
Note | Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached aluminium heatsink:50 W to 100 W: 200 × 200 × 6 [mm]200 W to 750 W: 250 × 250 × 6 [mm]Rates torque of 1 kW to 5 kW is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached iron heatsink:1 kW to 2 kW: 400 × 400 × 20 [mm]3 kW, 5 kW: 550 × 550 × 30 [mm] | |||
Electromagnetic brake specifications | Capacity | 18.5 W |