High-speed, High-accuracy CCD Laser Displacement Sensor

LK-G3000 series

Catalogues View Catalogue

All-in-one controller, PNP output LK-G3001PV

LK-G3001PV - All-in-one controller, PNP output

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking

Specifications

Model

LK-G3001PV*1

Separate type

LK-G3001P/LK-GD500*2

Type

All-in-one model

Head compatibility

All LK-G sensor heads are compatible

Connectable number of heads

Maximum of 2 units

Display

Minimum display unit

0.01 µm

Display range

±9,999.99 mm to ±9,999.99 µm (Selectable from six levels)

Display cycle

10 times/sec.

Terminal block

Analogue voltage output

±10 V x 2 outputs, output impedance: 100 Ω

Analogue current output

4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω

Timing input

For OUT1, voltage input

Reset input

Auto-zero input

Laser remote interlock input

Non-voltage input

Comparator output

For OUT1, PNP open-collector output

Alarm output

For OUT1, PNP open-collector output (N.C.)

Expansion connector

Timing input

For OUT2, voltage input

Reset input

Auto-zero input

Program switching input

Voltage input x 3 inputs

Laser-Off input

For Head A/Head B, voltage input

Comparator output

For OUT2, PNP open-collector output

Alarm output

For OUT2, PNP open-collector output (N.C.)

Binary

Binary output

Measured data output (21 bits), OUT1/OUT2 selectable, PNP open-collector output

Strobe output

PNP open-collector output

Binary selector output

Binary selector input

Voltage input

RS-232C interface

Measured data output and control input/output (Maximum baud rate: 115,200 bps, selectable)

USB interface

In conformity with USB Revision 2.0 Full speed (USB1.1 compatible)

Major functions

2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO,
Sampling frequency setting, Mutual interference prevention, Data storage, 8-program memory, ECO mode,
ABLE setting, Target setting, ABLE tuning, Selection of measurement surface of transparent target,
Statistics processing, Connection of setting support software, Selectable head-mounting, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

When connecting one measurement head 500 mA or less /
When connecting two measurement heads 600 mA or less

Environmental resistance

Ambient temperature

0 to +50 °C

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 480 g

*1 The rating of the PNP open collector: 50 mA max. (30 V max.), residual voltage of 1 V max.
The rating of voltage input: 10.2 V or more ON voltage (26.4 V max.) 0.6 mA or less OFF current.
*2 LK-G3001P can be operated singly. The measured value display and setting modifications can be performed on the display panel (LK-GD500) or via the setting support software (LK-H1W).

Data Sheet (PDF) Other Models