Radar Level Sensor
FR series
Specs Radar Level Sensor FR series
Sensor Unit
Model |
FR-S01 |
FR-SH01 |
FR-LM20 |
FR-LP20 |
FR-LS20 |
|||
Image |
|
|
|
|
|
|||
Type |
Short range Standard model |
Short range Compact liquid chemical model |
Long range Standard model |
Long range Liquid chemical model |
Long range Sanitary model |
|||
Measuring range |
Up to 1.5 m *1 |
Up to 20 m *1 |
||||||
Display range |
Up to 2 m *1 |
Up to 25 m *1 |
||||||
Measurable dielectric constant of medium |
2 or higher *2 |
|||||||
Resolution |
1 mm |
|||||||
Precision |
Up to 0.1 m: ±20 mm; |
Up to 0.1 m: ±10 mm; |
||||||
Response time |
0.4 s, 1.5 s, 4 s (default value), 10 s |
|||||||
Tank pressure |
-0.1 to +1 MPa |
-0.1 to +0.1 MPa |
-0.1 to +1 MPa |
-0.1 to +0.1 MPa |
-0.1 to +1 MPa |
|||
Material |
Tank interior |
Lens: PTFE |
Lens: PTFE |
Lens: PTFE |
Lens: PTFE |
Lens: PTFE |
||
Housing |
PBT PAR |
PPS PPSU |
PPS PET PAR |
PPS PPSU |
SUS304 |
|||
Connection diameter |
G3/4 (20 A) |
G1-1/2 (40 A) |
2 S ferrule |
|||||
Output |
No. of control outputs |
Maximum 5 |
─ |
Maximum 5 |
||||
Control output/auxiliary output |
NPN/PNP open collector (switching type) |
NPN/PNP open collector (switching type) |
||||||
Analogue output |
0–20 mA/4–20 mA maximum load resistance 260 Ω |
0–20 mA/4–20 mA maximum load resistance 260 Ω |
||||||
External input |
Short-circuit current: 1.5 mA or less |
─ |
||||||
Network compatibility |
IO-Link v1.1/COM2 |
─ |
IO-Link v1.1/COM2 |
|||||
Analogue output Precision |
Resolution |
1 mm *4 |
1 mm *4 |
|||||
Zero accuracy |
±0.1 mA (zero point = 4 mA) *4 |
±0.1 mA (zero point = 4 mA) *4 |
||||||
Analogue output accuracy |
F.S. accuracy |
±0.2 mA (full-scale = 20 mA) *4 |
±0.2 mA (full-scale = 20 mA) *4 |
|||||
Power supply |
Power voltage |
24 VDC + 25%/–20% |
24 VDC + 25%/–20% |
|||||
Current consumption |
80 mA or less (Excluding Load Current) |
106 mA or less (Excluding Load Current) |
98 mA or less (Excluding Load Current) |
106 mA or less (Excluding Load Current) |
||||
Environmental resistance |
Ambient temperature |
−20°C to +55°C *5 *6 |
–10 to +70°C *5 *6 |
Display part when combined and separated: –20 to +50°C (no freezing) *5 *6 |
Display part when combined and separated: –10 to +50°C (no freezing) *5 *6 |
−20°C to +60°C *5 *6 |
||
Relative humidity |
Up to 85% RH (no condensation) |
|||||||
Temperature of coupling used |
–20 to +85°C (no freezing) *5 *6 |
–10 to +85°C (no freezing) *5 *6 |
–20 to +85°C (no freezing) *5 *6 |
–10 to +85°C (no freezing) *5 *6 |
–20 to +100°C (no freezing) *5 *6 |
|||
Vibration resistance |
10–500 Hz Power spectral density: 0.816 G2; X, Y and Z directions |
|||||||
Shock resistance |
100 m/s2 (10 G), 16 ms pulses, 1000 times each for X, Y and Z directions |
|||||||
Enclosure rating |
IP67 (IEC60529) |
IP67 (IEC60529), Enclosure Type 4X (NEMA250) |
IP67 (IEC60529), |
|||||
Protection circuit |
Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges |
|||||||
Weight |
Approx. 170 g |
Approx. 140 g |
Approx. 600 g |
Approx. 400 g |
Approx. 900 g |
|||
*1 Guaranteed value in water with the recommended installation. Static water can be measured up to the edge of the lens. An undetectable area on the short-range side is created owing to the environment and measurement medium. The maximum measuring distance is also shortened. |
Amplifier unit
Model |
FR-SA1 |
FR-SA2 |
FR-SA1C |
FR-SA0 |
|||
Image |
|
|
|
|
|||
Type |
Short Separated Amplifier Unit Cable Main Unit |
Short Separated Amplifier Unit Cable Expansion Unit |
Short Separated Amplifier Unit M8 connector Main Unit |
Short Separated Amplifier Unit Zero line Expansion unit |
|||
Response time |
0.4 s, 1.5 s, 4 s (default value), 10 s |
||||||
Output |
No. of control outputs |
Maximum 5 |
Maximum 2 |
0 |
|||
Control output/auxiliary output |
NPN/PNP open collector (switchable) up to 30 VDC or less, max 50 mA for each |
NPN/PNP open collector (switchable) |
─ |
||||
Analogue output |
0–20 mA/4-20 mA |
─ |
0–20 mA/4–20 mA |
||||
External input |
Short circuit current: 1.5 mA or less Input time: 500 ms or more |
||||||
External communication |
— |
NU Series |
IO-Link v1.1/COM2 |
NU Series |
|||
Analogue output Precision |
Resolution |
1 mm *1 |
— |
1 mm *1 |
─ |
||
Zero accuracy |
±0.1 mA (zero point = 4 mA) *1 |
±0.1 mA (zero point = 4 mA) *1 |
|||||
Full-scale accuracy |
±0.2 mA (full-scale = 20 mA) *1 |
±0.2 mA (full-scale = 20 mA) *1 |
|||||
Expansion |
When added to FR-SA1 (FR-S01 connection): Up to 8 units |
— |
When connected with NU Series: |
||||
Power supply |
Power voltage |
24 VDC +25%/−20%*4*5 including ripple, Class2 or LPS |
|||||
Power consumption |
When FR-S01 is connected: up to 1940 mW or less (72 mA or less at 24 V) |
When FR-S01 is connected: up to 1690 mW or less (60 mA or less at 24 V) |
1880 mW or less (63 mA or less at 24 V) (Excluding Load Current) |
1620 mW max. (53 mA max. at 24V) (Excluding Load Current) |
|||
Environmental resistance |
Ambient temperature |
–20°C to +55°C (no freezing) *6 |
|||||
Relative humidity |
Up to 85% RH (no condensation) |
||||||
Protection circuit |
Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges |
||||||
Material |
PC |
||||||
Weight |
Approx. 100 g |
Approx. 90 g |
Approx. 20 g |
||||
*1 This is the guaranteed value from verification performed at KEYENCE inspection facilities with a load resistance of 250 Ω. Measurement errors may occur depending on the customer’s environment. |