Specs Network Compatible Pressure Sensor AP-N series

Sensor heads (Detection components)

Model

AP-41M

AP-41

AP-43

AP-44

AP-48

Image

Application

Gauge pressure

Differential pressure

Type

Negative pressure

Positive pressure

Compound pressure

Rated pressure

0 to -101.3 kPa

0 to 1 Mpa

+101.3 to -101.3 kPa

-101.3 to +101.3 kPa

Fluid type

Air, non-corrosive gasses

Temperature characteristics

±2 % of F.S. (When the temperature varies from 25 °C)

Pressure port

M3 male threaded

M5 male threaded

R1/8

Environmental resistance

Pressure resistance

500 kPa

1.5 MPa

500 kPa

Ambient temperature

0 to +50 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 4 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 10 times in each of X, Y and Z directions, total of 60 times

Material

Case: PBT, Screw: SUS303, Cable: PVC

Weight

Approx. 68 g (including cable)

Approx. 70 g (including cable)

Approx. 98 g (including cable)

Back to top

Sensor amplifiers (Display devices)

Model

AP-N10

AP-N10D

Image

Type

Single output type

Dual output type

Applicable sensor head

AP-41M, AP-41, AP-43, AP-44, AP-48

Configuration/Display range

-15 to +110 % of F.S.

Repeatability

±0.2 % of F.S.

Display resolution

AP-41M/41/44/48: Standard mode 0.1 kPa, High resolution mode 0.01 kPa
AP-43: Standard mode 0.001 MPa, High resolution mode 0.1 kPa

Power consumption

Normal

770 mW or less (at 24 V, 32 mA or less/at 12 V, 54 mA or less)

Expansion units

Max. 16 units (Dual output type is counted as 2 units.)*1

Control output(s)

1*2

2*2

Display temperature characteristic

±1 % of F.S. (When the temperature varies from 25 °C)

Response time (Chattering prevention function)

1 ms/2.5 ms/5 ms/100 ms/500 ms/1,000 ms/5,000 ms selectable

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % max. Class2

Power consumption

Eco mode

560 mW or less (at 24 V, 23 mA or less/at 12 V, 37 mA or less)

Environmental resistance

Ambient temperature

0 to +50 °C (No freezing)*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Main unit and cover: Polycarbonate

Weight

Approx. 20 g

*1 Can connect to other N-bus sensor amplifiers. N-bus represents the wire-saving system for KEYENCE-manufactured sensor amplifiers.
*2 Number of outputs when connected to the communication unit NU-Series. There are no control output wires.
*3 11 to 16 units connected: 0 to +45 °C (When the sensor amplifier is installed on DIN rail on a metal plate)

Back to top